99久久国产综合精品成人影院,久久人人添人人爽添人人片AV,色窝窝亚洲AV网在线观看,色偷偷色噜噜狠狠网站久久

全國服務(wù)咨詢熱線:

15618996225

當(dāng)前位置:首頁  >  產(chǎn)品中心  >  太赫茲  >  太赫茲功率計(jì)  >  Mm-Wave power meter高靈敏度毫米波功率計(jì)

高靈敏度毫米波功率計(jì)

簡要描述:高靈敏度毫米波功率計(jì)Features
0.01-220 GHz operating frequency
High sensitivity
Up to 55 dB dynamic range (0.1uW-30mW)
Small measuring time (< 1 sec)
RS-232, GPIB interface
SCPI protocol

  • 產(chǎn)品型號:Mm-Wave power meter
  • 更新時(shí)間:2024-09-02
  • 訪  問  量:667

產(chǎn)品簡介

品牌其他品牌產(chǎn)地類別進(jìn)口
應(yīng)用領(lǐng)域農(nóng)業(yè),電子,汽車,電氣

詳細(xì)介紹

 

高靈敏度毫米波功率計(jì)Features  
  • 0.01-220 GHz operating frequency

  • High sensitivity

  • Up to 55 dB dynamic range (0.1uW-30mW)

  • Small measuring time (< 1 sec)

  • RS-232, GPIB interface

  • SCPI protocol

高靈敏度毫米波功率計(jì)Applications  
  • Recommended for use by Rohde & Schwarz

  • Measurements of power level of mm-wave signal

  • Test equipment

Description

The DPM-xx is a single-channel average power meter for RF to millimeter wave frequencies that measures absolute power from 10 MHz to 220 GHz.

DPM-xx Power Meters display measured power in milliWatts, microWatts or dBm, and also display the user-entered signal frequency in GHz. Easy operation is ensured with automatic zeroing, automatic sensor recognition and a calculation factor table stored in the memory of each power sensor.

Their compact size, precise accuracy, reliability and inexpensive pricing make our DPM-xx Power Meters attractive assets for design engineering, equipment manufacturing, field engineering and research.

ELVA-1’s ZBD-series Zero-Biased Detectors are used as the power sensors for our DPM Power Meters.To cover the range from 10MHz to 220GHz band, we offer one coaxial (10 MHz-26.5 GHz) and 9 waveguide power sensors (26.5-220 GHz in waveguide bands), sold separay.

Based on Schottky Barrier Diode technology, our ZBD power sensors provide high sensitivity, fast measurement speed and quick response to changes of input power. To extend the dynamic range of diode power sensors above their square law region, a correction factor is used. The amplitude and frequency curves for each individually-calibrated power sensor are stored in the sensor’s EEPROM. When a sensor is connected to a DPM control/display unit, the control/display unit automatically recognizes that sensor’s characteristics. The typical curves for amplitude and frequency transfer characteristics at W-band are shown on the reverse.

Measured average power is displayed on a 2-line LCD screen, at a measurement rate of 2 times per second or faster. For power measurements below 10-100mW (depending on frequency band), each sensor is supplied with a full-band isolator. For power measurements above those levels (as high as 300mW-1Watt), optional directional couplers are available.

Every DPM-xx is equipped with an RS-232 port for control and measurement data exchange with a PC. An internal GPIB interface board is available as an added option. On special request we can also provide a dual channel power meter of DPMD-XX series with two independent measurement channels.

Since the control/display unit and power sensors are sold separay, customers only need one DPM control/display unit to interface with all 10 of our sensors. To obtain power measurements over a multi-waveguide frequency range, order one DPM control/display unit and several adjacent-band sensors.  Because the standard ELVA-1 DPM control/display unit is a single-channel meter, only one power sensor can be used at one time.

 

DPM-XX Key Features and Specifications

- Display readings: milliWatts, microWatts or dBm

- Maximum measuring rate: up to 50 times per second, default 2 times per second (set at factory)

- Frequency Range: 10 MHz to 220 GHz

- Min. measured Power: 0.1 microWatt (depending on frequency band)

- Dynamic Measurement Range: 55dB max. (depending on frequency band)

- Frequency step: 10 MHz

- SCPI or ELVA’s command protocol

- RS-232, GPIB interface

- Calibration accuracy ±0.04 dB (log) or ±1%

- Power Sensor Calibration: Individually calibrated, with amplitude and frequency curves in flash memory

- If a valid signal frequency is not entered before measuring power, maximum measurement error will be ±1.5dB for Ka, Q, U, V bands, ±2.0dB for E, W bands, and ±2.5dB for F, D bands, based on calibration curve flatness.

Model Number DPM-C DPM -28 DPM -22 DPM -19 DPM -15 DPM -12 DPM -10 DPM -08 DPM -06 DPM -05
Frequency Band Ka Q U V E W F D G
Frequency Range, GHz 0.01-26.5 14757 33-50 40-60 50-75 60-90 75-110 90-140 110-170 140-220
Input Waveguide/Impedance 50 Ohm, Coaxial WR-28 WR-22 WR-19 WR-15 WR-12 WR-10 WR-08 WR-06 WR-05
Wavequide Flange/Connector SMA, male UG-599/U UG-383/U UG-383/U-M UG-385/U UG-387/U UG-387/U-M UG-387/U-M UG-387/U-M UG-387/U-M
Dynamic Range, dB (max) 50 55 55 55 55 55 55 55 50 40
Min Measured Power Level, dBm -33 -43 -43 -43 -43 -43 -40 -40 -35 -25
Measurement Rate (default), times per sec 2 2 2 2 2 2 2 2 2 2
VSWR (power sensor) 1.2:1 1.3:1 1.3:1 1.3:1 1.3:1 1.4:1 1.4:1 1.4:1 1.4:1 1.4:1

Available operating power options: 220 VAC, 110/100 VAC, or battery power (for portable version).

 

產(chǎn)品咨詢

留言框

  • 產(chǎn)品:

  • 您的單位:

  • 您的姓名:

  • 聯(lián)系電話:

  • 常用郵箱:

  • 省份:

  • 詳細(xì)地址:

  • 補(bǔ)充說明:

  • 驗(yàn)證碼:

    請輸入計(jì)算結(jié)果(填寫阿拉伯?dāng)?shù)字),如:三加四=7

全國統(tǒng)一服務(wù)電話

021-62209657

電子郵箱:sales@eachwave.com

公司地址:上海市閔行區(qū)劍川路955號707-709室

業(yè)務(wù)咨詢微信

狠狠干狠狠爱| 国产精品成人无码视频| 国内精品人妻无码久久久影院| 亚洲AV人无码激艳猛片服务器| 麻豆蜜桃AV蜜臀AV色欲AV| 两根一起进去疼拔出来| 亚洲国产精品久久AA片| 亚洲欧洲中文日韩久久AV乱码 | 极度性骚扰在线观看| 最近中文字幕2019视频1| 亚洲AV永久无码国产精品久久| 免费无码又爽又刺激软件下载直播 | 双XING挨CAO日常美人多汁| 狠狠躁夜夜躁人人爽| 门卫老头吸允校花奶头| 熟妇人妻AV中文字幕老熟妇| 熟妇高潮精品一区二区三区 | 久久亚洲精品成人AV无码网站 | 成人AV在线观看| 宝贝几天没C你了好爽菜老板 | 小舞两腿乳液自慰羞羞漫画| 欧美AV噜噜狠狠网址蜜桃 | 亚洲色精品三区二区一区| 国产又色又爽又黄刺激蜜臀AV| AV无码精品一区二区三区四区| 男按摩师按摩奶头是正常的吗| 国产小受呻吟GV视频在线观看| 理科生坠入情网电视剧免费观看| 无码国产69精品久久久久孕妇| 欧洲精品码一区二区三区免费看| 欧洲多毛裸体XXXXX| 欧亚乱熟女一区二区在线| 久久精品国产亚洲AV网站| 无码精品人妻一区二区三区APP| 久久亚洲精品中文字幕| 乌克兰肥妇黑毛BBW| 久久国产加勒比精品无码| 丝袜老师张开腿任我玩弄| 日本少妇ASS浓精PICS| 丁香花在线观看免费观看| 大内密探零零性性|